Critical guidelines for validation of the selectivity of in-vivo chemical microsensors
TrAC Trends in Analytical ChemistryPublished 1 September 2003
Paul E. M. Phillips, R. Mark Wightman
Citations114
SJR quartileQ1
SJR score2.09
SNIP2.29
Generate an AI Snapshot to get a quick, structured summary of this paper.
Study Snapshot
ObjectiveStudy objective
MethodsResearch methodology
PopulationPopulation studied
Sample sizeSample sizes
OutcomesStudy outcomes here
ResultsStudy results comes here
LimitationsResearch study limitations comes here
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
Abstract
Microsensors are miniaturized analytical devices for making in-situ chemical measurements in biological systems with extraordinary temporal resolution. Their most severe limitation is chemical selectivity. Here, we suggest guidelines that can be applied to a range of in-vivo microsensor applications for evaluation of analyte identification and improvement of selectivity.
Keywords
Biochemistry, Genetics and Molecular BiologyEngineeringChemical Engineering
NatureSubsecond dopamine release promotes cocaine seeking
1,116 Citations2003Paul E. M. Phillips, Garret D. Stuber +3 more
An unprecedented role for dopamine in the regulation of drug taking in real time is revealed using electrochemical technology to investigate the role of phasic dopamine signalling in the nucleus accumbens.
Proceedings of the National Academy of SciencesTemporally resolved catecholamine spikes correspond to single vesicle release from individual chromaffin cells.
891 Citations1991R. Mark Wightman, Janusz Jankowski +7 more
These measurements represent time-resolved observation of quantal secretion of catecholamine and provide direct evidence for the exocytotic hypothesis.
Brain ResearchNafion-coated electrodes with high selectivity for CNS electrochemistry
631 Citations1984Greg A. Gerhardt, Arvin F. Oke +3 more
A major improvement in the selectivity of small graphite electrodes used for in vivo electrochemistry is described, which becomes selective for the cationic primary neurotransmitters, dopamine, norepinephrine and 5-hydroxytryptamine.
NatureIn vivo electrochemical detection of catechols in the neostriatum of anaesthetized rats: dopamine or DOPAC?
417 Citations1980François Gonon, Michel Buda +3 more
The DPV method used in conjunction with an electrochemical treatment of this electrode yields stable and reproducible peaks in which catecholamines and AA are resolved from each other, suggesting that the technique may be a useful means of following dopaminergic activity in vivo.
Analytical ChemistrySubsecond Adsorption and Desorption of Dopamine at Carbon-Fiber Microelectrodes
376 Citations2000Bradley D. Bath, Darren J. Michael +4 more
High-repetition fast-scan cyclic voltammetry and chronoamperometry were used to quantify and characterize the kinetics of dopamine and dopamine-o-quinone adsorption and desorption at carbon-fiber microelectrodes, and voltammetrically measured uptake kinetics in the caudate are faster using 2,000 V/s and 240 Hz measurements.
Journal of NeurosciencePresynaptic Recording of Quanta from Midbrain Dopamine Neurons and Modulation of the Quantal Size
321 Citations1998Emmanuel N. Pothos, Viviana Davila +1 more
The observation of quantal release from central catecholamine neurons has proven elusive because of the absence of evoked rapid postsynaptic currents, so a means to measure directly the number of transmitter molecules released from small synaptic vesicles of CNS neurons is introduced.
Analytical ChemistryDesign and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
309 Citations1991Dilbir S. Bindra, Yanan Zhang +5 more
A new miniaturized glucose oxidase based needle-type glucose microsensor has been developed for subcutaneous glucose monitoring and exhibits good selectivity against common interferences except for the exogenous drug acetaminophen.
Analytical ChemistrySelf-Referencing Ceramic-Based Multisite Microelectrodes for the Detection and Elimination of Interferences from the Measurement of <scp>l</scp>-Glutamate and Other Analytes
289 Citations2001Jason J. Burmeister, Greg A. Gerhardt
This electrode has been applied to in vivo measurements of the clearance of locally applied glutamate and release of glutamate in the prefrontal cortex of anesthetized rats and the development of a microelectrode for measures of glucose.
Journal of NeuroscienceFrequency of Dopamine Concentration Transients Increases in Dorsal and Ventral Striatum of Male Rats during Introduction of Conspecifics
287 Citations2002Donita L. Robinson, Michael L. Heien +1 more
It is established for the first time that transient dopamine fluctuations occur throughout the dorsal and ventral striatum of male rats and demonstrate that they are more frequent with salient stimuli that elicit a response behavior.
Analytical ChemistryMonitoring Glutamate and Ascorbate in the Extracellular Space of Brain Tissue with Electrochemical Microsensors
228 Citations1999Nadezhda V. Kulagina, Latha Shankar +1 more
The in vivo measurements performed establish the ability of the glutamate microsensors to monitor the component of the basal extracellular glutamate level that is derived from the neuronal activity of brain tissue.
Journal of Neuroscience MethodsImproved ceramic-based multisite microelectrode for rapid measurements of l-glutamate in the CNS
224 Citations2002Jason J. Burmeister, François Pomerleau +4 more
Improvements and further characterization of a ceramic-based multisite microelectrode for in vivo measurements of L-glutamate are described, including increased recording area, insulation deposition using photolithography for more uniform recording sites and forming the microElectrodes using a diamond saw providing smoother microelectROde edges.
Journal of NeurochemistryCorrelation of local changes in extracellular oxygen and pH that accompany dopaminergic terminal activity in the rat caudate–putamen
156 Citations2003B. Jill Venton, Darren J. Michael +1 more
It is concluded that changes in blood flow accompanying terminal activity cause alkaline pH shifts by the rapid removal of carbon dioxide, a component of the extracellular brain buffering system.
NeuroreportSub-second changes in accumbal dopamine during sexual behavior in male rats
146 Citations2001Donita L. Robinson, Paul E. M. Phillips +4 more
The observed dopamine transients represent the first direct correlation of dopamine with sexual behavior on a sub-second time scale and dramatically improve the time resolution.
NeuroscienceIn vivo voltammetry—Present electrodes and methods
145 Citations1988C.A. Marsden, M. H. Joseph +5 more
Revue de l'interet de differentes methodes de voltametrie in vivo in vivo pour mesurer les metabolites chez l'animal anesthesie ou conscient, pour evaluer les flux de neuro-transmetteurs apres stimulation and Pour mesurer le niveau des catecholamines dans l'espace extracellulaire.
Journal of Neuroscience MethodsEffects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry
94 Citations2001Greg A. Gerhardt, Alexander F. Hoffman
Life SciencesA new type of enzyme electrode: The ascorbic acid eliminator electrode
82 Citations1982Géza Nagy, Margaret E. Rice +1 more
A new type of enzyme electrode has been developed for in vivo electrochemical measurements which allows discrimination between ascorbic acid and catecholamines and their metabolites and has been tested in brain slice measurements and shown to respond to releases of catechlamines initiated by potassium ion stimulation.
Neuroscience LettersAn amperometric enzyme electrode for monitoring brain glucose in the freely moving rat
75 Citations1986Martyn G. Boutelle, S. Clare Stanford +3 more
Brain glucose concentration was measured with an amperometric enzyme electrode using glucose oxidase (EC 1.3.4) irreversibly adsorbed onto an organic conducting salt and its stability both in vitro and in vivo are described.
Brain ResearchSimultaneous voltammetric and chemical monitoring of dopamine release in situ
75 Citations1985Margaret E. Rice, Arvin F. Oke +2 more
The results fully confirm that selectivevoltammetric electrodes can detect released DA and that the concentrations determined voltammetrically or chemically agree well.
Journal of Neuroscience MethodsInterference by pH and Ca2+ ions during measurements of catecholamine release in slices of rat amygdala with fast-scan cyclic voltammetry
62 Citations1994Sara R. Jones, George E. Mickelson +3 more
Fast-scan cyclic voltammetry at carbon-fiber microelectrodes was used to investigate catecholamine release and uptake induced by local electrical stimulation of rat brain slices containing the basolateral amygdaloid nucleus, and the observed release is proportionately smaller than that of the striatum.
Analytical ChemistryElectrochemical assay for brain ascorbate with ascorbate oxidase
53 Citations1982James O. Schenk, Ellen Miller +1 more
For optimum precision, the response of the Analyzer should be kept large by selecting the syringe size according to the sulfur content of the analyte and maintaining a reasonably rapid syringe drive speed.
Journal of Neuroscience MethodsDependence of dopamine calibration factors on media Ca2+ and Mg2+ at carbon-fiber microelectrodes used with fast-scan cyclic voltammetry
49 Citations1998June Kume‐Kick, Margaret E. Rice
For both electrode types, dopamine calibration factors, and thus electrode sensitivities, were 2-3-fold higher in phosphate- or HEPES-buffered saline than in a bicarbonate-based artificial CSF that reflected that normal ionic composition of brain extracellular fluid.
Journal of Electroanalytical ChemistrypH-Dependent processes at Nafion®-coated carbon-fiber microelectrodes
41 Citations1993Kirk T. Kawagoe, Paul A. Garris +1 more
