The D0 Silicon Microstrip Tracker
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentPublished 22 December 2010Open access
S. N. Ahmed, R. Angstadt, M. Aoki, B. Åsman, Sam M. Austin, L. Bagby
Citations51
Generate an AI Snapshot to get a quick, structured summary of this paper.
Study Snapshot
ObjectiveStudy objective
MethodsResearch methodology
PopulationPopulation studied
Sample sizeSample sizes
OutcomesStudy outcomes here
ResultsStudy results comes here
LimitationsResearch study limitations comes here
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
Abstract
\n Contains fulltext :\n 92417.pdf (Author’s version preprint ) (Open Access)\n
Keywords
Engineering
Physical Review LettersObservation of the Top Quark
1,296 Citations1995S. Abachi, B. Abbott +401 more
The D0 collaboration reports on a search for the Standard Model top quark in p{bar p} collisions at {radical}s = 1.8 TeV at the Fermilab Tevatron, with an integrated luminosity of approximately 50 pb{sup {minus}1}.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentThe upgraded DØ detector
608 Citations2006V. M. Abazov, B. Abbott +814 more
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentThe DØ detector
462 Citations1994S. Abachi, M. Abolins +336 more
DESY Publication Database (PUBDB) (Deutsches Elektronen-Synchrotron)Radiation damage in silicon particle detectors: Microscopic defects and macroscopic properties
211 Citations2022M. Moll
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentThe muon system of the Run II DØ detector
124 Citations2005V. M. Abazov, B. S. Acharya +138 more
IEEE Transactions on Nuclear ScienceRadiation hardness of silicon detectors: current status
69 Citations1997R. Wunstorf
IEEE Transactions on Nuclear ScienceThe SVX2 readout chip [Si strip detector]
19 Citations1995T. Zimmerman, M. Sarraj +5 more
SVX2 is essentially an upgrade of the presently used SVX chip and contains extensive performance and feature enhancements and is designed to accommodate much shorter beam crossing times with minimal increase in noise and power.
1995 IEEE Nuclear Science Symposium and Medical Imaging Conference RecordSVX/silicon detector studies
2 Citations2002L. Bagby, M. Johnson +2 more
The test results show that neighboring channels saturate when an excessive voltage is applied directly to a SVX channel, and it is believed that the effects are due to current diffusion within the SVX substrate rather than surface currents on the detectors.
