It is shown here that three‐dimensional π pulses are feasible on commercial imaging machines provided that the range of offresonance frequencies are limited.
Abstract
In theory, multidimensional pulses can be designed to be selective in any number of dimensions. In practice, available gradient power has enforced a limit to two dimensions. We show here that three-dimensional pi pulses are feasible on commercial imaging machines provided that the range of off-resonance frequencies are limited.
Keywords
MedicinePhysics and Astronomy
IEEE Transactions on Medical ImagingParameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)
777 Citations1991John M. Pauly, Patrick Le Roux +2 more
An overview of the Shinnar-Le Roux (SLR) algorithm is presented and it is shown how the performance of SLR pulses can be very accurately specified analytically, and how to design a pulse that produces a specified slice profile.
Magnetic Resonance in MedicineSimultaneous spatial and spectral selective excitation
503 Citations1990Craig H. Meyer, John M. Pauly +2 more
Using a k‐space interpretation of small‐tip excitation, a single excitation pulse has been designed that is simultaneously selective in space and resonant frequency that has been applied to a rapid gradient‐echo imaging sequence that forms both water and fat images within a breath‐holding interval.
Journal of Magnetic Resonance (1969)A k-space analysis of small-tip-angle excitation
490 Citations1989John M. Pauly, Dwight G. Nishimura +1 more
Journal of Magnetic Resonance (1969)A linear class of large-tip-angle selective excitation pulses
176 Citations1989John M. Pauly, Dwight G. Nishimura +1 more
Journal of Applied PhysicsBroadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity
139 Citations1989Christopher J. Hardy, H. E. Cline
Magnetic Resonance in MedicineThe synthesis of pulse sequences yielding arbitrary magnetization vectors
120 Citations1989Meir Shinnar, Scott M. Eleff +2 more
A new procedure and algorithm are presented to allow the synthesis of a pulse sequence which will generate an arbitrary frequency‐dependent spin excitation, and enables us to generate any Mz which is potentially realizable by a pulse sequences.
Magnetic Resonance in MedicineCoronary angiography using fast selective inversion recovery
83 Citations1991Samuel J. Wang, Bob S. Hu +2 more
Using a fast version of selective inversion recovery, coronary angiograms of normal volunteers showing the proximal portions of the left coronary artery are obtained using a 2D inversion pulse.
Magnetic Resonance in Medicine<sup>31</sup>P Spectroscopic localization using pinwheel NMR excitation pulses
47 Citations1991Christopher J. Hardy, Paul A. Bottomley
A two‐dimensional cylindrically selective excitation pulse with a large spectral bandwidth is presented here to remedy the problem of relatively poor localization in these dimensions ofSpectroscopic imaging with a one‐dimensional phase‐encoding gradient and surface‐coil reception.
Magnetic Resonance in MedicineSpectroscopic imaging with multidimensional pulses for excitation: SIMPLE
42 Citations1991Daniel M. Spielman, John M. Pauly +2 more
Use of multidimensional selective‐excitation pulses (e.g., pulses that are simultaneously selective along two axes) to both define the ROI and provide the necessary water suppression are discussed.
Magnetic Resonance in MedicineLocalized volume selection technique using an additional radial gradient coil
28 Citations1989S. Y. Lee, Z. H. Cho
A volume selection technique for the localized NMR imaging using an additional radial gradient using the use of the radial gradient in conjunction with the selective RF pulse thereby selecting a small cylindrical volume which can be used for the 3‐ dimensional volume imaging with fewer encoding steps than those of the conventional full 3‐dimensional volume imaging.
Magnetic Resonance in MedicineApplication of Single‐Shot Spiral Scanning for Volume Localization
8 Citations1991J. B., C. Y. Rim +1 more
The proposed method appears simple and accurate in localizing a volume which would be used as either fast imaging or localized Spectroscopy.