The Diagnostic Performance of Computer Programs for the Interpretation of Electrocardiograms
New England Journal of MedicinePublished 19 December 1991Open access
Jos L. Willems, Cassiano Abreu‐Lima, P Arnaud, Jan H. van Bemmel, Christian Brohet, R. Degani
Citations543
SJR quartileQ1
SJR score19.08
SNIP13.47
Generate an AI Snapshot to get a quick, structured summary of this paper.
Study Snapshot
ObjectiveStudy objective
MethodsResearch methodology
PopulationPopulation studied
Sample sizeSample sizes
OutcomesStudy outcomes here
ResultsStudy results comes here
LimitationsResearch study limitations comes here
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
TL;DR
It is shown that some but not all computer programs for the interpretation of ECGs perform almost as well as cardiologists in identifying seven major cardiac disorders.
Abstract
Our study shows that some but not all computer programs for the interpretation of ECGs perform almost as well as cardiologists in identifying seven major cardiac disorders.
Keywords
Medicine
BiometricsThe Measurement of Observer Agreement for Categorical Data
78,934 Citations1977J. Richard Landis, Gary G. Koch
A general statistical methodology for the analysis of multivariate categorical data arising from observer reliability studies is presented and tests for interobserver bias are presented in terms of first-order marginal homogeneity and measures of interob server agreement are developed as generalized kappa-type statistics.
Journal of the American College of CardiologyCriteria for intraventricular conduction disturbances and pre-excitation
394 Citations1985Jos L. Willems, Etienne O. Robles de Medina +13 more
Criteria for the diagnosis of conduction disturbances and pre-excitation patterns for clinical electrocardiography are reviewed by an Ad Hoc Working Group established by the World Health Organization and the International Society and Federation of Cardiology.
The American Journal of CardiologyComparison of the classification ability of the electrocardiogram and vectorcardiogram
52 Citations1987Jos L. Willems, Emmanuel Lesaffre +1 more
The conventional 12-lead ECG is as good as the VCG for the differential diagnosis of 7 main entities, provided identical procedures are used in the design of the classifiers.
American Heart JournalPerformance of the computer and physician in the analysis of the electrocardiogram
49 Citations1970Cesar A. Cáceres, Howard M. Hochberg
CirculationA Method for Evaluating Computer Programs for Electrocardiographic Interpretation
48 Citations1974James J. Bailey, Samuel B. Itscoitz +3 more
Journal of ElectrocardiologySurvey of computer-assisted electrocardiography in the United States
38 Citations1988Erica L. Drazen, Nancy K. Mann +3 more
This study indicates that additional information on accuracy of current ECG software is needed to ensure that the technology is optimally applied in patient care.
European Heart JournalEffect of combining elecrocardiographic interpretation results on diagnostic accuracy
32 Citations1988Jos L. Willems, Cassiano Abreu‐Lima +12 more
Findings demonstrate that the combination of expert knowledge of computer programs can, similar to panel review and group analysis in clinical practice, enhance diagnostic accuracy.
Methods of Information in MedicineReference Standards for Software Evaluation
22 Citations1990Stefan Wellek, J. L. Willems +1 more
The evaluation methodology used within the CSE project is described as a basis for presentation of results which are published elsewhere in this issue.
The American Journal of CardiologyReliability and normal variations of computer analysis of frank electrocardiogram by Smith-Hyde program (1968 version)
22 Citations1972Robert A. Bruce, Stephen R. Yarnall +4 more
There were more significant differences in voltage magnitudes of ventricular repolarization than of either atrial or ventricular depolarization in relation to sex and age of healthy persons.
Computers and Biomedical ResearchEvaluation of computer-ECG programs. The strange case of the golden standard
20 Citations1979Pentti M. Rautaharju, Ph. Smets
It is demonstrated that the apparent performance of a program being tested is always worse than that of the standard even if the program were absolutely perfect.
CirculationComparative evaluation of the IBM (12-lead) and Royal Infirmary (orthogonal three-lead) ECG computer programs.
17 Citations1981P. W. Macfarlane, Diane Melville +2 more
A comparison of two computer programs for ECG interpretation was undertaken and GRI was judged correct in 119 of these disagreements and IBM in 70, while the remaining 33 disagreements had to be classified inconclusive.
The American Journal of CardiologyClinical evaluation of automated processing of electrocardiograms by the Veterans Administration program (AVA 3.4)
10 Citations1979Christian Brohet, Harold Richman
Clinical acceptability of the Veterans Administration program appears to require greater physician education than that needed for other computer programs of electrocardiographic analysis; the flexibility of interpretation by statistical decision offers the potential for better diagnostic accuracy.
Journal of ElectrocardiologyProgress on the CSE diagnostic study
9 Citations1990Jos L. Willems, Gregory Campbell +1 more
An extension of McNemar's test that can be used to compare diagnostic performance when multiple statements are obtained from computer analysis or visual interpretation of the ECG is described, giving partial credit for the one correct statement and partial discredit for any incorrect statement.
DMW - Deutsche Medizinische WochenschriftComputeranalyse des Elektrokardiogramms mit verschiedenen Programmen
9 Citations1974J. Meyer, K. W. Heinrich +2 more
Journal of ElectrocardiologyComparative diagnostic performance of the telemed computer ECG program
7 Citations1983Paul Bernard, Bernard Chaitman +3 more
Criteria changes in the most recent version of the Telemed program have not resulted in a major change in diagnostic performance, and arrhythmia detection is slightly but not significantly improved.
Journal of ElectrocardiologyThe impact of the computer-reported vectorcardiogram on the cardiologist interpreter of the scaler electrocardiogram
5 Citations1977John A. Milliken, Gary W. Burggraf +1 more
It was concluded that the use of a computer-assisted interpretation of a VCG may enhance the uniformity and consistency of the cardiologist's interpretation of the scalar ECG.
Advances in cardiologyMultigroup Diagnostic Classification with a New �Maximal� Lead System
3 Citations2015F. Kornreich, P C Block +8 more
