Myocardial Protection during Aortic Valve Replacement
Generate an AI Snapshot to get a quick, structured summary of this paper.
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
TL;DR
The results following aortic valve replacement (AVR) show that the myocardium is preserved best during AVR when continuous coronary perfusion is used and the heart is maintained in the beating state.
Abstract
The results following aortic valve replacement (AVR) were compared in 40 patients in whom the myocardium was protected by topical hypothermic arrest or continuous coronary perfusion with sustained electrical fibrillation (Group A) and 40 similar patients in whom the hearts were also continuously perfused but were kept in the beating state (Group B). The operative mortality was not greatly different between the two groups, being 10 and 5%, respectively. The postperfusion cardiac performance was strikingly different, however. Seventeen patients (43%) in Group A required inotropic support, while this was necessary in only 1 patient (3%) in Group B. In this instance, recurrent ventricular fibrillation persisted despite attempts at reversion. These data show that the myocardium is preserved best during AVR when continuous coronary perfusion is used and the heart is maintained in the beating state.