EKG artifacts suppression from the EEG
Electroencephalography and Clinical NeurophysiologyPublished 1 September 1991
Lawrence H. Larsen, Patricia N. Prinz
Citations11
Generate an AI Snapshot to get a quick, structured summary of this paper.
Study Snapshot
ObjectiveStudy objective
MethodsResearch methodology
PopulationPopulation studied
Sample sizeSample sizes
OutcomesStudy outcomes here
ResultsStudy results comes here
LimitationsResearch study limitations comes here
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
TL;DR
A method is proposed to identify and eliminate EKG artifacts from a single channel of EEG recordings and it is proposed that the algorithm may be applied universally to all EEG recordings.
Abstract
A method is proposed to identify and eliminate EKG artifacts from a single channel of EEG recordings. The method identifies the EKG as outlying data in the EEG. The algorithm may be applied universally to all EEG recordings.
Keywords
MedicineNeuroscience
The Annals of StatisticsRobust Regression: Asymptotics, Conjectures and Monte Carlo
2,356 Citations1973Peter J. Huber
Wiley eBooksUnderstanding robust and exploratory data analysis
1,876 Citations1983David C. Hoaglin, Frederick Mosteller +1 more
Journal of the Royal Statistical Society Series A (General)Understanding Robust and Exploratory Data Analysis.
1,171 Citations1984D. Collett, David C. Hoaglin +2 more
Estimators of Location: An Outline of the Theory (C. Goodall).
Journal of Mathematical PhysicsAn exact recursion for the composite nearest-neighbor degeneracy for a 2×<i>N</i> lattice space
925 Citations1984R. B. McQuistan, J.L. Hock
Electroencephalography and Clinical NeurophysiologyA balanced non-cephalic reference electrode
187 Citations1951Will Stephenson, F. A. Gibbs
A relatively quiet reference facilitates interpretation, and the balanced reference electrode recommended here is relatively quiet even when focal abnormality occurs in the inferior portions of the brain, so as to utilize the base of the neck as a common reference for EEG recording.
Journal of the Royal Statistical Society Series B (Statistical Methodology)Robust Estimation of Power Spectra
172 Citations1979Beat Kleiner, R. Douglas Martin +1 more
Electroencephalography and Clinical NeurophysiologyElimination of EKG artifacts from EEG records: a new method of non-cephalic referential EEG recording
58 Citations1987Masatoshi Nakamura, Hiroshi Shibasaki
By the high speed implementation of the procedure, the processed data of multi-channel EEGs can be obtained on-line with a delay of only 200 msec, and the average EKG wave form can adapt appropriately to a change of the artifact wave form.
Electroencephalography and Clinical NeurophysiologyEEG markers of early Alzheimer's disease in computer selected tonic REM sleep
47 Citations1992Patricia N. Prinz, Lawrence H. Larsen +2 more
The frequency spectra during tonic REM sleep revealed a significant shift towards slower wave forms in AD vs. control subjects, indicating that these sleep EEG changes are apparently predictive of AD status.
Electroencephalography and Clinical NeurophysiologyEKG-artifact minimization in referential EEG recordings by computer subtraction
13 Citations1980John S. Barlow, Janet M. Dubinsky
A computer-based on-line real-time subtraction technique for minimization of EKG artifact in clinical EEG recordings, especially those employing a non-cephalic reference, is described.
Electroencephalography and Clinical NeurophysiologyElimination of EKG artifacts from EEGs recorded with balanced non-cephalic reference electrode method
9 Citations1982Yoji Ishiyama, Mituru Ebe +2 more
The EKG artifacts contaminating EEGs recorded by the balanced non-cephalic reference electrode system were removed from EEGs by using a device composed of a one channel averager and simple hardware and it was felt that the method was sufficiently accurate for clinical examination of EEG.
