Solubility of Acetylene in Lung Tissue as an Error in Cardiac Output Determination with the Acetylene Method

Acta Physiologica ScandinavicaPublished 1 September 1963
R. Jernérus, G. Lundin, Lorene Pugh
Citations450

TL;DR

The solubility of acetylene in lung tissue is measured by a rebreathing technique and enough acetylene is dissolved in the lung tissue to simulate an extra gaseous lung volume between 0.274–0.48 liters, which should give an error of 7–12 % in cardiac output determination with the acetylene rebreather method.

Abstract

Abstract The solubility of acetylene in lung tissue is measured by a rebreathing technique. Enough acetylene is dissolved in the lung tissue to simulate an extra gaseous lung volume between 0.274–0.48 liters. This should give an error of 7–12 % in cardiac output determination with the acetylene rebreathing method.