Ten years of HIV testing with fourth generation assays: The Amsterdam experience
Journal of Clinical VirologyPublished 17 October 2011
Suzanne Jurriaans, Nicole Back, Katja C. Wolthers
Citations17
SJR quartileQ1
SJR score1.19
SNIP0.90
Generate an AI Snapshot to get a quick, structured summary of this paper.
Study Snapshot
ObjectiveStudy objective
MethodsResearch methodology
PopulationPopulation studied
Sample sizeSample sizes
OutcomesStudy outcomes here
ResultsStudy results comes here
LimitationsResearch study limitations comes here
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
TL;DR
The Academic Medical Center is one of the main HIV treatment centers in the Netherlands and has now 10 years experience with fourth generation testing, which is summarized here.
Abstract
Serological HIV assays combining detection of HIV antigen and antibodies are referred to as fourth generation assays. Fourth generation assays were implemented in Europe for routine patient testing about 10 years ago. The Academic Medical Center is one of the main HIV treatment centers in the Netherlands and has now 10 years experience with fourth generation testing, which is summarized here.
Keywords
Immunology and MicrobiologyMedicine
Annals of EpidemiologyReemergence of the HIV Epidemic Among Men Who Have Sex With Men in North America, Western Europe, and Australia, 1996–2005
324 Citations2009Patrick S. Sullivan, Osamah Hamouda +15 more
After declining in the second half of the 1990s, HIV notification rates for MSM increased beginning in 2000, and are not wholly explained by changes in HIV testing.
AIDSOngoing HIV-1 transmission among men who have sex with men in Amsterdam: a 25-year prospective cohort study
119 Citations2010Irálice AV Jansen, Ronald B. Geskus +5 more
Following increases in sexual risk behaviour from 1996 onwards, HIV-1 continues to spread among MSM, and targeted prevention messages should continue to focus on sexual behaviour with casual partners, but also onSexual behaviour within steady relationships.
Journal of Clinical MicrobiologyFourth-Generation Enzyme-Linked Immunosorbent Assay for the Simultaneous Detection of Human Immunodeficiency Virus Antigen and Antibody
90 Citations2001Rebecca D. Saville, Niel T. Constantine +6 more
The VIDAS HIV DUO Ultra is accurate, offers potential advantages over conventional HIV testing for time and cost savings, has walk-away capability, and correctly identifies both early and established HIV infections.
Journal of Clinical MicrobiologyHuman Immunodeficiency Virus (HIV) Antigen-Antibody Combination Assays: Evaluation of HIV Seroconversion Sensitivity and Subtype Detection
82 Citations2002Thoai Duong Ly
Results indicate that although all combination assays can detect antibodies to HIV-1, group M, subtypes A to G, circulating recombinant form (CRF) A/E, and HIV- 1 group O, their sensitivity varied considerably when tested using diluted HIV-2 antibody-positive samples.
Journal of Clinical MicrobiologySeven Human Immunodeficiency Virus (HIV) Antigen-Antibody Combination Assays: Evaluation of HIV Seroconversion Sensitivity and Subtype Detection
76 Citations2001Thoai Duong Ly, Lynn A. Martin +10 more
Results indicate that although all combination assays can detect antibodies to HIV-1, group M, subtypes A to G, circulating recombinant form (CRF) A/E, and HIV- 1 group O, their sensitivity varied considerably when tested using diluted HIV-2 antibody-positive samples.
Journal of Clinical VirologyThe risk of a second diagnostic window with 4th generation HIV assays: Two cases
21 Citations2009Christoph Niederhauser, Angelika Ströhle +3 more
The rare occurrence of a second diagnostic window with 4th generation HIV assays strongly suggests that the following up testing algorithms need to be adjusted accordingly.
