Comparative evaluation of Aptima HIV-1 Qualitative RNA assay performance using plasma and serum specimens from persons with established HIV-1 infection
Journal of Clinical VirologyPublished 17 October 2011
Steven F. Ethridge, Laura G. Wesolowski, Muazzam Nasrullah, Melanie S. Kennedy, Kevin P. Delaney, Debra Candal
Citations9
SJR quartileQ1
SJR score1.19
SNIP0.90
Generate an AI Snapshot to get a quick, structured summary of this paper.
Study Snapshot
ObjectiveStudy objective
MethodsResearch methodology
PopulationPopulation studied
Sample sizeSample sizes
OutcomesStudy outcomes here
ResultsStudy results comes here
LimitationsResearch study limitations comes here
A concise AI-generated summary of the paper will appear here once you click Generate AI Snapshot.
TL;DR
In specimens from persons with established infections, Aptima performed with similar sensitivity when used with serum or plasma, and using serum for immunoassay screening and supplemental testing may provide added convenience for laboratories.
Abstract
In specimens from persons with established infections, Aptima performed with similar sensitivity when used with serum or plasma. Using serum for immunoassay screening and supplemental testing may provide added convenience for laboratories.
Keywords
Immunology and MicrobiologyMedicine
AIDSDynamics of HIV viremia and antibody seroconversion in plasma donors
1,276 Citations2003Eberhard Fiebig, David J. Wright +9 more
The sequential emergence of assay reactivity allows the classification of primary HIV-1 infection into distinct laboratory stages, which may facilitate the diagnosis of recent infection and stratification of patients enrolled in clinical trials.
Clinical Microbiology ReviewsLaboratory diagnosis and interpretation of tests for syphilis
753 Citations1995Sandra A. Larsen, B M Steiner +1 more
On the horizon are a number of direct antigen, enzyme-linked immunosorbent assay, and PCR techniques that have shown promise in clinical trials for the diagnosis of congenital syphilis and neurosyphilis that are presently difficult to diagnose.
New England Journal of MedicineDetection of Acute Infections during HIV Testing in North Carolina
374 Citations2005Christopher D. Pilcher, Susan A. Fiscus +13 more
The addition of nucleic acid amplification testing to an HIV testing algorithm significantly increases the identification of cases of infection without impairing the performance of diagnostic testing.
TransfusionTime course of detection of viral and serologic markers preceding human immunodeficiency virus type 1 seroconversion: implications for screening of blood and tissue donors
365 Citations1995Michael P. Busch, L. L. L. Lee +7 more
Recent improvement in the sensitivity of anti‐HIV assays has resulted in significant shortening of the preseroconversion window period, and the incremental reduction in the window period that could be achieved by implementing direct virus‐detection Assays has diminished significantly.
AIDSUse of laboratory tests and clinical symptoms for identification of primary HIV infection
294 Citations2002Frederick Hecht, Michael P. Busch +8 more
Rash and fever indicated the highest risk of primary HIV infection (PHI), and HIV-1 RNA tests are very sensitive for PHI but false-positive results occur.
Journal of Clinical MicrobiologyAlternative Algorithms for Human Immunodeficiency Virus Infection Diagnosis Using Tests That Are Licensed in the United States
164 Citations2008S. Michele Owen, Chunfu Yang +16 more
The results indicate that alternative algorithm strategies with currently licensed tests compare favorably with the conventional algorithm in detecting and confirming established HIV infection and there was improved detection of early infection.
Archives of Internal MedicineDetecting Acute Human Immunodeficiency Virus Infection Using 3 Different Screening Immunoassays and Nucleic Acid Amplification Testing for Human Immunodeficiency Virus RNA, 2006-2008
119 Citations2010Pragna Patel
Targeted AHI screening using pooled NAAT after third-generation testing increases HIV case detection, especially in venues of high HIV seropositivity, warranting a cost-benefit analysis.
Journal of Clinical MicrobiologyEffects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma
106 Citations1997Christine C. Ginocchio, X P Wang +6 more
It is determined that when whole blood was processed within 2 h of specimen collection the levels of HIV-1 RNA detected in EDTA-, heparin-, and acid citrate dextrose (ACD)-anticoagulated plasma samples were comparable and indicates that EDTA-anticoAGulated plasma is the most suitable and stable matrix for HIV- 1 RNA quantitation.
AIDSTargeted screening for primary HIV infection through pooled HIV-RNA testing in men who have sex with men
89 Citations2005Joanne D. Stekler, Paul D. Swenson +3 more
Men who have sex with men (MSM) having HIV testing through Public Health, Seattle and King County were screened for primary infection through pooled RNA testing.
Journal of Clinical MicrobiologyCertain canine weakly beta-hemolytic intestinal spirochetes are phenotypically and genotypically related to spirochetes associated with human and porcine intestinal spirochetosis
61 Citations1995G Duhamel, Nagaraja Muniappa +5 more
The IS-associated canine, human, and porcine WBHIS belonged to a phyletic group distinct from but related to previously described Serpulina type species.
Expert Review of Anti-infective Therapy2010 HIV Diagnostics Conference
49 Citations2010Mark Pandori, Bernard M. Branson
During the 2010 HIV Diagnostics Conference, salient new data related to three aspects of HIV testing (rapid point-of-care testing, laboratory assays and new technologies) were presented and discussed.
Journal of Clinical MicrobiologyComparison of the Amplicor HIV-1 monitor test and the nucleic acid sequence-based amplification assay for quantitation of human immunodeficiency virus RNA in plasma, serum, and plasma subjected to freeze-thaw cycles
49 Citations1997Brigitte P. Griffith, Michael O. Rigsby +3 more
It is demonstrated that the Nasba and Amplicor assays perform similarly with plasma and serum samples, and that freeze-and-thaw cycles do not result in significant loss of detectable HIV RNA.
TransfusionClinical specificity and sensitivity of a blood screening assay for detection of HIV‐1 and HCV RNA
36 Citations2002Janet Vargo, Katie Smith +12 more
Donor plasma samples reactive in the Procleix HIV‐1/HCV assay are tested with the HIV-1 and HCV discriminatory assays to resolve whether HIV‐ 1 RNA, HCV RNA, or both are present.
Journal of Clinical VirologyPerformance of an alternative laboratory-based algorithm for diagnosis of HIV infection utilizing a third generation immunoassay, a rapid HIV-1/HIV-2 differentiation test and a DNA or RNA-based nucleic acid amplification test in persons with established HIV-1 infection and blood donors
31 Citations2011Laura G. Wesolowski, Kevin P. Delaney +7 more
The proposed algorithm performs with high sensitivity and specificity in specimens from persons with established HIV infection and uninfected blood donors and appears to be a good alternative to the current algorithm.
Journal of Clinical MicrobiologyStabilities of quantitative plasma culture for human immunodeficiency virus, RNA, and p24 antigen from samples collected in VACUTAINER CPT and standard VACUTAINER tubes
26 Citations1994L Molé, David M. Margolis +3 more
Interday variability suggests that samples collected for a particular assay should be processed at the same time after blood is drawn and that a particular tube type be used throughout a given study.
AIDSNucleic acid amplification testing for diagnosis of acute HIV infection: has the time come?
24 Citations2005Michael P. Busch, Frederick Hecht
Key observations from studies applying nucleic-acid amplification testing to diagnose pre-seroconvesion window-phase HIV-1 infections are reviewed, and issues impacting expanded use of NAT in donor screening, public health surveillance and diagnostic screening settings are addressed.
Journal of Clinical MicrobiologyPCR as a confirmatory test for human immunodeficiency virus type 1 infection in individuals with indeterminate western blot (immunoblot) profiles
15 Citations1995Su Yun Se-Thoe, Ai Ee Ling +3 more
A combination of two PCR systems which amplify human immunodeficiency virus type 1 (HIV-1) gag and pol DNA was used to elucidate the HIV-1 infection status of a group of individuals screening positive for anti-HIV but having indeterminate Western blot (immunoblot) profiles.
Clinical and Vaccine ImmunologyEvaluation of Oral Fluid Enzyme Immunoassay for Confirmation of a Positive Rapid Human Immunodeficiency Virus Test Result
11 Citations2009Laura G. Wesolowski, Travis Sanchez +6 more
The CDC recommends that a reactive rapid human immunodeficiency virus (HIV) test be confirmed with an approved supplemental test; the performance of an intermediate enzyme immunoassay (EIA) is optional.
Journal of Clinical MicrobiologyPerformance of the Aptima HIV-1 RNA Qualitative Assay with 16- and 32-Member Specimen Pools
11 Citations2010Steven F. Ethridge, Clyde E. Hart +7 more
The Aptima HIV-1 RNA qualitative assay tested with a WHO-approved HIV type 1 RNA standard in 16- and 32-member pools detected 100% of the pools, thus exceeding the FDA-required lower limit of detection.
